ESA title
8x8 array of 6 mm^2 SiPM detectors.
Enabling & Support

Scaleable Large-area SiPM

02/06/2017 1874 views 3 likes
ESA / Enabling & Support / Space Engineering & Technology / Shaping the Future
 Programme:  GSTP  Achieved TRL:  6
 Reference:  G628-002MM  Closure:  2017 
 Contractor(s):  SensL (IE)

 
While Silicon Photomultipliers (SiPM) are recognized high-performance detectors, the manufacturing process results in significant dead space when they are used to form larger arrays, which is frequently necessary for both space and ground-based applications. By developing a new SiPM manufacturing process using established Through-Silicon-Via (TSV) technology, detector arrays with minimal dead space should be feasible, offering greatly improved performance and compact detector design.

Objective(s)
To develop, qualify and make production ready, a ball-grid array (BGA) SiPM detector based on TSV technology

Top and bottom view of single 6x6 mm^2 SiPM detector
Top and bottom view of single 6x6 mm^2 SiPM detector

Achievements and status
The program saw the successful development of a large area TSV packaged SiPM which was subjected to a full characterisation, qualification and reliability assessment testing. Through this program SensL were able to develop a large area process technology required to package SiPM in a manner which allows them to be tiled with minimal dead space between sensors.

Benefits
The results of this activity has successfully lead to the development of a new product, the MicroFJ-60035-TSV which SensL is now selling to commercial customers. The process technology is also under consideration for future high-energy astronomy missions.

Next steps
SensL (click here for the news announcement on the SensL website) aims to have this technology adopted for medical scanner use – see link below for news announcement in this context - collaboration with United Imaging Healthcare and University California-Davis.